Sign In | Join Free | My burrillandco.com
Home > Multi Parameter Patient Monitor >

15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm

Hunan Province Rainbow Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm from wholesalers
     
    Buy cheap 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm from wholesalers
    • Buy cheap 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm from wholesalers
    • Buy cheap 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm from wholesalers
    • Buy cheap 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm from wholesalers
    • Buy cheap 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm from wholesalers
    • Buy cheap 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm from wholesalers
    • Buy cheap 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm from wholesalers

    15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm

    Ask Lasest Price
    Brand Name : RAINBOW
    Model Number : PM-9000GTE
    Certification : ISO13485
    Price : US $395.0 - 555.0
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 30000units/year
    Delivery Time : Within 3 days
    • Product Details
    • Company Profile

    15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm

    New Design 15.1 Inch Big Screen Medical Devices Cardiac Patient Monitoring For Hospital

    PM9000-GTE Product Specification

    15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm

    Product brief

    1.ARM9 main board + 7in1 monitor module; Based on embedded linux, the monitor have small size, high integration, low power and high performance
    2.Parameters include ECG, Respiration, NIBP, dual temperature,SpO2, pulse rate, dual IBP, CO₂ and 3.Multi-Gas
    4.Unique human voice alarm
    5.Full digital SpO2 technology with excellent performance in low perfusion and movement
    6.ECG monitoring include arrhythmia analysis, ST calculation and Pace analysis
    7.Protected against defibrillation, ESU and myoelectric artifact
    8.NIBP have dual over pressure protect, can operation correctly under severe environment to protect the patient
    9.Full alarm feature include 3 alarm level, alarm sound, alarm light and on screen alarm message
    10.Human voice alarm helps the user to identify the source of alarms


    15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm

    Specification

    15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm Warning 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm

    The patient monitor may not meet its performance specification if stored or used outside the manufacturer’s specified temperature and humidity range.

    1.1 Classification

    Anti-electroshock type Class I equipment

    Anti-electroshock degree CF defibrillation

    1.2 Accordant Standard

    Medical Device Directive 93/42/EEC
    EN60601-1:2005 or IEC60601-1:2005Medical Electrical Equipment, Part 1: General Requirements for Safety
    EN60601-1-1 or IEC60601-1-1Medical Electrical Equipment, Part 1-1: General Requirements for Safety, Collateral Standard: Safety Requirements for Medical Electrical Systems
    IEC60601-1-4Medical Electrical Equipment, Part 1-4: General Requirements for Safety, Collateral Standard: Programmable Electrical Medical Systems
    IEC60601-2-49Medical Electrical Equipment, Part 2-49: Particular Requirements for the Safety of Multifunction Patient Monitoring Equipment
    IEC 60601-1-2:2007Electromagnetic Compatibility, Medical Electrical Equipment
    ISO 21647:2009Medical electrical equipment — Particular requirements for the basic safety and essential performance of respiratory gas monitors

    1.3 Power Supply

    100~240 VAC, 50/60 Hz, Pmax=60VA

    1.4 Battery

    2200 mAh 14.8V rechargeable Lithium battery

    Operating time after full charge is more than 1.5 hours

    Operating time after the first alarm of low battery will be about 5 minutes

    Maximum charging time is less than 6 hours.

    1.5 Environment

    Temperature

    Working 0 ~ 40 °C, 5 ~ 40 °C with CO₂

    Storage -20 ~ 50°C

    Humidity

    Working 15% - 90 %

    Storage 15% - 90 % (no coagulation)

    1.6 Signal Interface

    Network interface standard RJ45 Socket

    USB port

    1.7 ECG

    1.7.1 Lead mode

    5 Leads, I, II, III, AVR, AVL, AVF, V

    1.7.2 Gain

    ´2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV

    1.7.3 Heart rate

    Measure range:

    Adult 15 ~ 300 bpm

    Neonatal/Pediatric 15 ~ 350 bpm

    accuracy ± 1%

    resolution 1 bpm

    1.7.4 Sensitivity

    > 200 μV P-P

    1.7.5 Differential Input Impedance

    > 5 M ohm

    1.7.6 CMRR

    Diagnostic Mode >90 dB

    Monitor Mode >110 dB

    Surgery Mode >110 dB

    1.7.7 Electrode offset potential

    ±300mV

    1.7.8 Leakage Current

    < 10 μA

    1.7.9 PACE pulse detect

    range ±2~±700mV

    width 0.1~2ms

    rise time 10~100µs

    1.7.10 PACE pulse rejection

    range ±2~±700mV

    width 0.1~2ms

    rise time 10~100µs

    1.7.11 Baseline Recovery

    < 3 s After defibrillation.

    1.7.12 Signal Range

    ± 5 mV p-p

    1.7.13 Bandwidth

    Surgery 1 ~ 20 Hz

    Monitor 0.5 ~ 40 Hz

    Diagnostic 0.05 ~ 130 Hz

    1.7.14 Calibration Signal

    1 mV p-p, ± 5% accuracy

    1.7.15 ST measurement

    range -2.0 ~ +2.0 mV

    Accuracy -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater

    Other range: unspecified

    1.8 Respiration

    1.8.1 Method

    Impedance between RA-LL or RA-LA

    1.8.2 Differential Input Impedance

    >2.5 M ohm

    1.8.3 Respiration Impedance Range

    0.3~3Ω

    1.8.4 Base Impedance Range

    200Ω-2000Ω

    1.8.5 Bandwidth

    0.3 ~ 2 Hz

    1.8.6 Gain

    ´0.25,´0.500,´1,´2,´4

    1.8.7 Respiration Rate

    Measurement Range

    Adult 0 ~ 120 BrPM

    Neonatal / Pediatric 0 ~ 150 BrPM

    Resolution 1 BrPM

    Accuracy 0~6 BrPM: unspecified

    7~150 BrPM: ±2 BrPM or ±2%, use the greater

    Inspiriting current < 300 µA RMS max

    1.8.8 Apnea Alarm

    10 ~ 40 s

    1.9 NIBP

    1.9.1 Method

    Oscillometry

    1.9.2 Measure mode

    Manual, Auto, STAT

    1.9.3 Measure Interval in AUTO Mode

    1,2,3,4,5,10,15,30,60,90,120,180,240,480 min

    1.9.4 Measure Period in STAT Mode

    5 min

    1.9.5 Pulse Rate Range

    40 ~ 240 bpm

    15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm

    1.1.1 Measure and Alarm Range

    Adult Mode

    SYS 40 ~ 280 mmHg

    DIA 10 ~ 220 mmHg

    MEAN 20 ~ 240 mmHg

    Pediatric Mode

    SYS 40 ~ 220 mmHg

    DIA 10 ~ 160 mmHg

    MEAN 20 ~ 170 mmHg

    Neonatal Mode

    SYS 35 ~ 135 mmHg

    DIA 10 ~ 100 mmHg

    MEAN 20 ~ 110 mmHg

    1.1.2 Static pressure accuracy

    ±3mmHg

    1.1.3 Resolution

    1mmHg

    1.1.4 Accuracy

    Maximum Mean error ±5mmHg

    Maximum Standard deviation 8mmHg

    1.1.5 Overpressure Protection

    Adult 300 mmHg

    Pediatric 240 mmHg

    Neonatal 150 mmHg

    1.1 SpO2

    1.1.1 Measurement Range

    0 ~ 100 %

    1.1.2 Resolution

    1 %

    1.1.3 Accuracy

    70% ~ 100% ±2 %

    0% ~ 69% unspecified

    1.1.4 Pulse Rate

    Measure and Alarm Range 20~250bpm

    Resolution 1bpm

    Accuracy ±3bpm

    1.2 Temperature

    Channel 2

    Measure and Alarm Range 0 ~ 50 °C

    Resolution 0.1°C

    Accuracy(no sensor) ± 0.1℃(25℃ – 45℃) ,± 0.2℃(other)

    Accuracy(include sensor) ± 0.2℃(32℃ - 42℃)

    ± 0.3℃(other)

    1.3 MASIMO Spo2 (optional)

    Measurement range 1 to 100%

    Resolution 1%

    Accuracy 70 to 100%: ±2% (measured without motion in adult/pediatricmode)

    70 to 100%: ±3% (measured with motion in neonate mode)

    70 to 100%: ±3% (measured with motion)

    0% to 69%: Not specified.

    Refreshing rate 1 s

    Updated period 8 s, 16 s

    Pulse Rate

    Measurement range 25 to 240 bpm

    Resolution 1 bpm

    Accuracy ±3 bpm (measured without motion)

    ±5 bpm (measured with motion)

    Refreshing rate 1 s

    Updated period 8 s, 16 s

    Low Perfusion

    Conditions Pulse amplitude: >0.02%

    Light penetration: >5%

    SpO2 accuracy ±2%

    PR accuracy ±3 bpm

    1.4 NELLCOR SpO(Optional)

    1.4.1 SpO2

    Range 0~100%

    resolution 1%

    accuracy 70~100%:±2%

    < 69%:undefined

    1.5 IBP(optional)

    1.5.1 Sensor

    reusable sensors:OHMEDA P23XL or BD,EDWARD compatible

    once usage:OHMEDA DT-4812 or BD,EDWARD compatible

    excitation voltage:+5Vdc±2%

    sensitivity:5uV/V/mmHg

    1.5.2 Channels

    2 channels

    1.5.3 Measuer Range

    -50~ 360(mmHg)

    1.5.4 Resolution

    1mmHg

    1.5.5 Accuracy(no sensor)

    ±2% or ±1mmHg, use the greater

    1.5.6 Band Width

    Normal mode: DC~40Hz

    Smooth mode: DC~12.5Hz

    1.6 CO(optional)

    1.6.1 Measuer Range

    0% ~ 13%

    1.6.2 Resolution

    1 mmHg

    1.6.3 Accuracy

    ±2 mmHg @ < 5.0% CO₂ (at ATPS)

    1.6.4 Breath Rate

    Breath Rate: 3 - 150 bpm

    1.7 Gas (optional)

    1.7.1 Measuer Range

    CO2 0 - 15 %

    N2O 0 - 100 %

    HAL, ISO, ENF 0 - 8 %

    SEV 0 - 10 %

    DES 0 - 22 %

    1.7.2 Accuracy

    CO2 ± (0.2 %ABS + 2 %REL)

    O2 ± (1 %ABS + 2 %REL)

    N2O ± (2 %ABS + 2 %REL)

    HAL, ISO, ENF ± (0.15 %ABS + 2 %REL)

    SEV ± (0.15 %ABS + 2 %REL)

    DES ± (0.15 %ABS + 2 %REL)

    1.7.3 Breath Rate

    Breath Rate: 0 - 150 bpm, ±1bpm

    1.8 Touch Screen (optional)

    1.8.1 Method

    4 wire resistor

    1.8.2 size

    12.1 inch

    1.9 Recorder(optional)

    Paper width 48 mm

    speed 25/50 mm/s

    wave channel 3 channels


    Quality 15.1 Inch Cardiac Multipara Patient Monitor dual IBP with human voice alarm for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hunan Province Rainbow Technology Co., Ltd.