Sign In | Join Free | My burrillandco.com
Home > Maternal Fetal Monitor >

Medical Multi Parameter Maternal Fetal Monitor For Pregnant Women And Fetus

Hunan Province Rainbow Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Medical Multi Parameter Maternal Fetal Monitor For Pregnant Women And Fetus from wholesalers
     
    Buy cheap Medical Multi Parameter Maternal Fetal Monitor For Pregnant Women And Fetus from wholesalers
    • Buy cheap Medical Multi Parameter Maternal Fetal Monitor For Pregnant Women And Fetus from wholesalers
    • Buy cheap Medical Multi Parameter Maternal Fetal Monitor For Pregnant Women And Fetus from wholesalers
    • Buy cheap Medical Multi Parameter Maternal Fetal Monitor For Pregnant Women And Fetus from wholesalers

    Medical Multi Parameter Maternal Fetal Monitor For Pregnant Women And Fetus

    Ask Lasest Price
    Brand Name : RAINBOW
    Model Number : PM-9000E
    Certification : ISO13485, FSC
    Price : Negotiable
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 30000units/year
    Delivery Time : Within 3 days
    • Product Details
    • Company Profile

    Medical Multi Parameter Maternal Fetal Monitor For Pregnant Women And Fetus

    Basic information:

    Nine parametersFHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP
    Size12.1 inch portable maternal fetal monitor
    Weight3.55kg(with build-in two channel thermal printer)
    Voltage220v
    Power40w
    Leads3-5 leads
    Suitable placeshospital departments bedside care ward, ICU, CCU, operating theaters, prenatal care unit emergency centers, family care and the like.
    Optionalmobile stand/wall mount
    SFDA classificationClass II
    Working systemContinuous running equipment

    Features:

    new high-precision modules, new digital oxygen technology

    12" color TFT display, up to 12 waveforms

    3 in 1 transducers, no cable inter twisting.
    Arrhythmia analysis, ST calculation, Pace analysis

    Various interfaces: A single guide, standard, large font, all leads
    Anti-ESU, anti- defibrillator

    Patient info input management function

    Multi-lead ECG waveforms display in phase

    1-7 level audio/visual alarming

    Large volume of tabular and graphic trends information storage and easy to recall
    Built-in recorder and battery

    suitable for adults, children, newborns and unborn babies.


    Standard configuration:

    PM-9000E maternal fetal monitor×1 set,

    build-in dual channel thermal printer×1 set,

    triple fetal probe×1 set,

    ultrasound gel×1 bottom,

    probe bandages×1 set,

    standard 5-leads ECG conductance joint connecting cables×1 set,

    standard adult blood pressure cuffs×1 set,

    adult SPO2 probe×1 set,

    TEMP probe×1 set,

    power plug line×1 set,

    grounding wire×1 set,

    English operation manual×1 set.

    Three certificates×1 set.


    Optional:

    Build-in rechargeable lithium battery; monitor mobile stand/ cart.


    Technical Parameters

    FHR

    Probe: Nine wafer, wide beam, pulsed operation mode and high sensitivity.

    Ultrasound intensity: less than 1mW / cm²

    Operating frequency: 1.0MHz

    Signal Processing: dedicated digital signal processing unit

    Maximum Audio Output Power: 1.5W

    TOCO


    10-100 pressure unit


    Ultrasonic Probe Output


    In accordance with the provisions of the international convention in 1992, IEC1157, negative peak sound pressure of not more than l trillion Pa (MPa). Beam sound intensity does not exceed 20 mW / cm 2 (mW / cm ²). Sound intensity spatial peak temporal average density of less than 100 mW / cm (mW / cm ²). The models sound intensity does not exceed 1mw / cm ²

    Coupling Agent (GEL)


    Viscous water-based sets of objects. On the skin without stimulation, no allergies. Chemically stable, inhibit bacterial type.


    ECG

    lead mode;I,II,III,AVR,AVL,AVF,V1-6

    Gain: ×0.25, × 0. 5, and × 1, × 2

    Frequency: 0.5 Hz - 100 Hz

    Common-mode signal inhibition: More than 70 dB

    Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

    HR: ± 5 BPM

    Precision calibration signal: 1mv(peak, ± 3% accuracy)

    ST Detection: measurement range (-2.0mV----+2.0mV)

    Using Standard: meet the ANSI / AMI EC13 -2002 standard

    Response time: 1s

    Alarm: Sound and Light

    Preset heart rate range: (Alarm over preset numerical)

    Ceiling: 1-255 bpm adjustable

    Threshold: 0-254 bpm adjustable

    NIBP

    Technology: Oscillography

    Mode: manual / automatic

    Measurement units: mmHg / kPa

    Scope: Pressure Cuffs 0-250 mmHg

    Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn)

    Inflatable cuffs follow: original SBP: + 30 mmHg

    Measuring range: SYS: 60-250 mmHg

    DIA: 40-220 mmHg

    MEAN: 45-235 mmHg

    Response time: 1s

    Alarm: Sound and Light

    Preset range: report (Numerical exceed preset alarm)

    SYS: maximum: 1-255 mmHg adjustable

    Threshold: 0-254 mmHg adjustable

    DIA: ceiling: 1 -255 mmHg adjustable

    Minimum standards: 0-254mmHg adjustable

    SPO2

    Range: 0-100%

    Accuracy: 1%

    Resolution: 1%

    Pulse frequency: 20-250 times / min

    Response time: 1s

    Alarm: Sound and Light

    Preset range: (report Alarm over preset numerical)

    Ceiling: 1% - 100% adjustable

    Threshold: 0% - 99% adjustable

    TEMP

    Technology: thermostat temperature probe

    Measuring range: 20 ° C-45 ° C

    Temperature resolution: 0.1%

    Accuracy: ± 0.1 ° C

    Response Time: 1s

    Alarm: Sound and Light

    Preset range: report (numerical preset alarm over)

    Maximum: 20.1 ° C-45.5 ° C adjustable

    Threshold: 20 ° C-45.4 ° C Adjustable

    RESP

    Breathing frequency range: 0-60 bum

    Accuracy: ± 1rpm

    Response time: 1s

    Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches

    Alarm: Sound and Light

    Alarm range: (numerical preset alarm over)

    Ceiling: 10-100 bpm adjustable

    Threshold: 0 -99 bpm adjustable

    Printer(Optional)


    Specification: Dual channel thermal array data recorder

    Print mode: Real time or event triggered record waveform and text

    Accuracy: horizontal: 4oodpi vertical: 800dpi

    Annotation: Date/ time(24 hours)

    Optional wall bracket, mobile stand, visits backpack.

    System

    Screen:12.1 inches TFT screen of LCD

    Battery: sealed maintenance-free lithium battery

    Safety standard: lec601-1(GB9706.1)


    ECG

    lead mode;I,II,III,AVR,AVL,AVF,V1-6

    Gain: ×0.25, × 0. 5, and × 1, × 2

    Frequency: 0.5 Hz - 100 Hz

    Common-mode signal inhibition: More than 70 dB

    Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

    HR: ± 5 BPM

    Precision calibration signal: 1mv(peak, ± 3% accuracy)

    ST Detection: measurement range (-2.0mV----+2.0mV)

    Using Standard: meet the ANSI / AMI EC13 -2002 standard

    Response time: 1s

    Alarm: Sound and Light

    Preset heart rate range: (Alarm over preset numerical)

    Ceiling: 1-255 bpm adjustable

    Threshold: 0-254 bpm adjustable

    NIBP

    Technology: Oscillography

    Mode: manual / automatic

    Measurement units: mmHg / kPa

    Scope: Pressure Cuffs 0-250 mmHg

    Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn)

    Inflatable cuffs follow: original SBP: + 30 mmHg

    Measuring range: SYS: 60-250 mmHg

    DIA: 40-220 mmHg

    MEAN: 45-235 mmHg

    Response time: 1s

    Alarm: Sound and Light

    Preset range: report (Numerical exceed preset alarm)

    SYS: maximum: 1-255 mmHg adjustable

    Threshold: 0-254 mmHg adjustable

    DIA: ceiling: 1 -255 mmHg adjustable

    Minimum standards: 0-254mmHg adjustable

    SPO2

    Range: 0-100%

    Accuracy: 1%

    Resolution: 1%

    Pulse frequency: 20-250 times / min

    Response time: 1s

    Alarm: Sound and Light

    Preset range: (report Alarm over preset numerical)

    Ceiling: 1% - 100% adjustable

    Threshold: 0% - 99% adjustable

    TEMP

    Technology: thermostat temperature probe

    Measuring range: 20 ° C-45 ° C

    Temperature resolution: 0.1%

    Accuracy: ± 0.1 ° C

    Response Time: 1s

    Alarm: Sound and Light

    Preset range: report (numerical preset alarm over)

    Maximum: 20.1 ° C-45.5 ° C adjustable

    Threshold: 20 ° C-45.4 ° C Adjustable

    RESP

    Breathing frequency range: 0-60 bum

    Accuracy: ± 1rpm

    Response time: 1s

    Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches

    Alarm: Sound and Light

    Alarm range: (numerical preset alarm over)

    Ceiling: 10-100 bpm adjustable

    Threshold: 0 -99 bpm adjustable

    Printer(Optional)


    Specification: Dual channel thermal array data recorder

    Print mode: Real time or event triggered record waveform and text

    Accuracy: horizontal: 4oodpi vertical: 800dpi

    Annotation: Date/ time(24 hours)

    Optional wall bracket, mobile stand, visits backpack.

    System

    Screen:12.1 inches TFT screen of LCD

    Battery: sealed maintenance-free lithium battery

    Safety standard: lec601-1(GB9706.1)


    Packing

    Packing terms: Anti-collision film+ Carton box

    Carton box dimension: 40*30*35cm

    Gross weight: 6.30kg

    Shipping:

    Air shipping or Express courier is recommended if the order quantity was less than 20 units. It usually takes around 7 days to reach the destination. By ocean shipping, it normally takes 20-40 days depending on the destination port.

    What is your MOQ?

    1 unit

    What is your lead time?

    Within 3 days after receiving the payment

    What is the payment terms?

    TT(Bank Transfer), Paypal, Western Union, Moneygram, XTransfer.

    What is the warranty period?

    2 years warranty period

    Lifetime online technical support

    Do you offer OEM service?

    Yes, we do

    Quality Medical Multi Parameter Maternal Fetal Monitor For Pregnant Women And Fetus for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hunan Province Rainbow Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)